Home > Products

High Voltage Partial Discharge Test on Gis Circuit

  • RF08 Mini Series-modular Get Price!

    Service cart for SF6-gas handling of small to medium size gas-insulated equipment.

  • RF051 Economy Series SF6 Gas Handling Cart Get Price!

    For easy maintenance on high voltage switchgear Less than 220kv

  • RF391 Mega Series SF6 Gas Handling Unit Get Price!

    Maintenance device for large and extra large gas compartments.

  • RF300 SF6 Gas Purification for re-use System Get Price!

    SF6 recycling and re-use

  • S100 Micro Series SF6 Gas Recycling Device Get Price!

    Special application Recovery of a small amount of sf6 gas in a small SF6 Gas compartments.

  • RFJ SF6 Refilling Evacuating Devices Get Price!

    SF6 Gas Cylinder to Gas compartments

  • RA912 SF6 Gas Analyzer Get Price!

    For determining the quality of SF6 gas.he RA912 multi-functional analyzer allows the determination of up to seis quality parameters with only one measurement:SF6 concentration (%).Moisture concentration.SO2 concentration (ppmv).CO concentration (ppmv).H2S concentration (ppmv).Option: HF concentration (ppmv)

  • NA1013 SF6 Gas Monitoring System Get Price!

    For continuous monitoring of the SF6 quality.NA-1013 online infrared gas transmitter is base on the internet of things’s air quality monitoring instruments .It used online monitoring for toxic gases, SF6 gas, O2, temperature, humidity, etc. Fast response, high accuracy, with a variety of selectable signal output mode.Passed through the third grade EMC industry test. Compliance with IEEE 802.15.4 wireless communication standard, ZigBee communication protocol support

  • Smart SF6 Sensor Get Price!

    NDIR SF6 Sensor 10 years life for SF6 Gas Leakage detection.Measurement principle: Dual wavelength, Non Dispersive Infra-Red (NDIR).Measurement range: 0-50/1000/1500ppm.Gas supply: by diffusion (atmospheric pressure).Warm-up time: < 2 minutes (start-up time).< 11 minutes (fade in finished).< 30 minutes (full specification).Measuring response.Response time (t90): appr. 60 s.Digital resolution (@ zero): 1 ppm.Repeatability: ≤ ± 15 ppm.

  • non-partial discharge test equipment for high voltage switchgearGeneral informationThe system is especially designed for testing GIS in the factory and on-site test, and for testing all GIS switchgears and GIS components such as insulators, insulating tension pole, GIS PT etc. It also can test trans
    • AC High Voltage Circuit Breakers - IEEE Web HostingGet Price!

      · PDF 文件1. AC High-Voltage Circuit Breaker 2. SF 6 and Alternatives 3. Rated Characteristics 4. Operating Mechanism 5. Arcing Phenomena in HV Circuit Breakers 6. Arc Extinction Principles 7. Switching Duties 8. Standards Related to High-Voltage Circuit Breakers 9. Annexes Annex 1 on TRV Annex 2 on New Test Procedure T100a Annex 3 on Transformer Limited.

    • Gas-insulated Switchgear (GIS) Testing - OMICRONGet Price!

      This has a negative influence on their insulation behavior, which can then be diagnosed by partial discharge measurements. When commissioning GIS, it is also necessary to perform a voltage withstand test in line with the standards (IEC 62271-203).

    • Gas-insulated switchgearGet Price!

      Gas-insulated high-voltage switchgear (GIS) is a compact metal encapsulated switchgear consisting of high-voltage components such as circuit-breakers and disconnectors, which can be safely operated in confined spaces. GIS is used where space is limited, for example, extensions, in city buildings, on roofs, on offshore platforms, industrial.

    • Testing Distribution Switchgear for Partial DischargeGet Price!

      · PDF 文件across the polymeric insulation of an 11kV circuit breaker. Fig. 1: Surface PD activity on an 11kV circuit breaker. Low discharge amplitude, high discharge rate 2.2 INTERNAL PARTIAL DISCHARGE Within all insulation material, however manufactured, microscopic voids or cracks are present. When under

    • China Best Price High Voltage Switch Dynamic.Get Price!

      Circuit Breaker Tester, 400 Omicron Circuit Breaker Tester Price, Circuit Breaker Test Set manufacturer / supplier in China, offering Best Price High Voltage Switch Dynamic Characteristics Circuit Breaker Tester, China Partial Discharge Analyzer for Transformers, Switchgear, Cable and Gis, 15 Kv Megohmmeter Test Device 15kv Digital Insulation Resistance Tester and so on.

    • Quality High Voltage Cable Testing Equipment & AC Get Price!

      WUHAN FANKE HAIWO HIGH VOLTAGE TECHNOLOGY CO.,LTD. is best High Voltage Cable Testing Equipment, AC Resonant Test System and AC Hipot Test Equipment supplier, we has good quality products & service from China.

    • Partial discharge - WikipediaGet Price!

      Overview

    • Partial Discharges in Electrical InsulationGet Price!

      · PDF 文件What is Partial Discharge (PD) •PD only occurs where there is a gas (air, SF6, hydrogen) between the two conductors •The conductors must have a high voltage between them, creating an electric stress •If the electric stress in the gas exceeds 3 kV/mm of spacing (for most dry gases at 100 kPa), then electrons are stripped from the gas atoms




    Email: [email protected]

    Send your Inquiry

    Inquiry

    Using our contact forms you can also send inquiries, give feedback, request information and ask questions.
    Email:
    [email protected]