Home > Products

Partial Discharge Free Detecting System Testing Tr

  • RF08 Mini Series-modular Get Price!

    Service cart for SF6-gas handling of small to medium size gas-insulated equipment.

  • RF051 Economy Series SF6 Gas Handling Cart Get Price!

    For easy maintenance on high voltage switchgear Less than 220kv

  • RF391 Mega Series SF6 Gas Handling Unit Get Price!

    Maintenance device for large and extra large gas compartments.

  • RF300 SF6 Gas Purification for re-use System Get Price!

    SF6 recycling and re-use

  • S100 Micro Series SF6 Gas Recycling Device Get Price!

    Special application Recovery of a small amount of sf6 gas in a small SF6 Gas compartments.

  • RFJ SF6 Refilling Evacuating Devices Get Price!

    SF6 Gas Cylinder to Gas compartments

  • RA912 SF6 Gas Analyzer Get Price!

    For determining the quality of SF6 gas.he RA912 multi-functional analyzer allows the determination of up to seis quality parameters with only one measurement:SF6 concentration (%).Moisture concentration.SO2 concentration (ppmv).CO concentration (ppmv).H2S concentration (ppmv).Option: HF concentration (ppmv)

  • NA1013 SF6 Gas Monitoring System Get Price!

    For continuous monitoring of the SF6 quality.NA-1013 online infrared gas transmitter is base on the internet of things’s air quality monitoring instruments .It used online monitoring for toxic gases, SF6 gas, O2, temperature, humidity, etc. Fast response, high accuracy, with a variety of selectable signal output mode.Passed through the third grade EMC industry test. Compliance with IEEE 802.15.4 wireless communication standard, ZigBee communication protocol support

  • Smart SF6 Sensor Get Price!

    NDIR SF6 Sensor 10 years life for SF6 Gas Leakage detection.Measurement principle: Dual wavelength, Non Dispersive Infra-Red (NDIR).Measurement range: 0-50/1000/1500ppm.Gas supply: by diffusion (atmospheric pressure).Warm-up time: < 2 minutes (start-up time).< 11 minutes (fade in finished).< 30 minutes (full specification).Measuring response.Response time (t90): appr. 60 s.Digital resolution (@ zero): 1 ppm.Repeatability: ≤ ± 15 ppm.

  • Application:It is mainly used for testing frequency voltage insulation level of various insulation materials, insulation structure and electrical products, also as partial discharge frequency testing power supply for testing object such as transformer, mutual inductor and lightning arresters. It wid
    • Partial Discharge Free Detecting System 100kV Test Get Price!

      Partial Discharge Free Detecting System 100kV test transformer. I Standard. JB / T9641 "test transformer" GB1094 "Power Transformer" GB50150-91-2006 "electrical installation installation of electrical equipment transfer test standards" DL / T 848 · 3-2004 "General technical conditions for high voltage test equipment" Part 3: No PD test transformer

    • Testing Distribution Switchgear for Partial DischargeGet Price!

      · PDF 文件Partial discharge activity has long been accepted as a major cause of failure of HV/MV switchgear, [1 & 2]. Traditional techniques for the detection of partial discharge involved taking plant out of service and energising via a discharge free power supply and measuring signals using coupling capacitors and conventional PD detectors e.g.文件大小: 345KB

    • Partial DischargeGet Price!

      Partial discharge surveys. We carry out systematic testing of HV equipment using state-of-the-art testing equipment. We are able to detect both internal and external sources of partial discharge. No outage or shut down is required, meaning no disruption to your network.

    • China Partial Discharge, China Partial Discharge.Get Price!

      Partial Discharge Free Detecting System Testing Transformer no partial discharge test transformer Xuanzhaotong Electric Manufacturing (Baoding) Co., Ltd. US $10000-$15000 / Set

    • Professional Partial Discharge Test Equipment Impulse.Get Price!

      III. Detecting principle figure . Note : The PD free test transformer set (power frequency voltage withstand test set) rises the target testing voltage to tested object (such as power transformer ,CB, bushing, CT,PT ,discloser and so on )which PD detecting needed , the coupling terminals of voltage divider will has some PD coupling signal to the PD detecting tester JF 2002, then get the PD.

    • Partial discharge - WikipediaGet Price!

      Overview




    Email: [email protected]

    Send your Inquiry

    Inquiry

    Using our contact forms you can also send inquiries, give feedback, request information and ask questions.
    Email:
    [email protected]