Home > Products

Power-Frequency Partial Discharge Test Equipment

  • RF08 Mini Series-modular Get Price!

    Service cart for SF6-gas handling of small to medium size gas-insulated equipment.

  • RF051 Economy Series SF6 Gas Handling Cart Get Price!

    For easy maintenance on high voltage switchgear Less than 220kv

  • RF391 Mega Series SF6 Gas Handling Unit Get Price!

    Maintenance device for large and extra large gas compartments.

  • RF300 SF6 Gas Purification for re-use System Get Price!

    SF6 recycling and re-use

  • S100 Micro Series SF6 Gas Recycling Device Get Price!

    Special application Recovery of a small amount of sf6 gas in a small SF6 Gas compartments.

  • RFJ SF6 Refilling Evacuating Devices Get Price!

    SF6 Gas Cylinder to Gas compartments

  • RA912 SF6 Gas Analyzer Get Price!

    For determining the quality of SF6 gas.he RA912 multi-functional analyzer allows the determination of up to seis quality parameters with only one measurement:SF6 concentration (%).Moisture concentration.SO2 concentration (ppmv).CO concentration (ppmv).H2S concentration (ppmv).Option: HF concentration (ppmv)

  • NA1013 SF6 Gas Monitoring System Get Price!

    For continuous monitoring of the SF6 quality.NA-1013 online infrared gas transmitter is base on the internet of things’s air quality monitoring instruments .It used online monitoring for toxic gases, SF6 gas, O2, temperature, humidity, etc. Fast response, high accuracy, with a variety of selectable signal output mode.Passed through the third grade EMC industry test. Compliance with IEEE 802.15.4 wireless communication standard, ZigBee communication protocol support

  • Smart SF6 Sensor Get Price!

    NDIR SF6 Sensor 10 years life for SF6 Gas Leakage detection.Measurement principle: Dual wavelength, Non Dispersive Infra-Red (NDIR).Measurement range: 0-50/1000/1500ppm.Gas supply: by diffusion (atmospheric pressure).Warm-up time: < 2 minutes (start-up time).< 11 minutes (fade in finished).< 30 minutes (full specification).Measuring response.Response time (t90): appr. 60 s.Digital resolution (@ zero): 1 ppm.Repeatability: ≤ ± 15 ppm.

  • Application:It is mainly used for testing frequency voltage insulation level of various insulation materials, insulation structure and electrical products, also as partial discharge frequency testing power supply for testing object such as transformer, mutual inductor and lightning arresters. It wid
    • China Power Frequency Partial Discharge Testing Get Price!

      Hipot Test, High Voltage Test Set, High Voltage Testing Equipment manufacturer / supplier in China, offering Power Frequency Partial Discharge Testing Equipment /AC Hipot Tester, Hipot Tester for Insulation Tester Withsand Voltage Testing Equipment, Hm 220 Underground Pipeline Locator Pipe and Cable Locator and so on.

    • Power-Frequency Partial Discharge Hipot Tester Test Get Price!

      Testing Equipment, Test Device, Testing Machine manufacturer / supplier in China, offering Power-Frequency Partial Discharge Hipot Tester Test Equipment, Factory Price Mask Making Machine Non-Woven Fabric Electret Electrostatic Generator, Hot Sale Mask Machine Non-Woven Fabric Electret Electrostatic Generator and so on.

    • The Basics of Partial Discharge Testing | HV Get Price!

      What is Partial Discharge? When speaking of partial discharge, the most important standard that every expert will refer to is IEC 60270: High-voltage test techniques – Partial discharge measurements.This standard applies to the measurement of PD in electrical apparatus or systems when testing with AC voltage up to 400 Hz or with DC voltage.

    • Power frequency Non Partial Discharge test set(100kVA.Get Price!

      Power frequency No Partial Discharge testing set is used for checking the insulation level of power-frequency voltage for all kinds of insulation materials and electric products, which is widely used in electric products manufactures, electric power operation departments, scientific research institutions, colleges & universities. It is a.

    • 150kV Non Partial Discharge Power Frequency Testing.Get Price!

      Non partial discharge power frequency testing transformer for high voltage test. I Standard. IEC60-1 high voltage test technology. DL / T 846.1 General specification for high voltage test equipment - Part 1: High voltage divider measurement system. GB / T16927.1 High voltage test technology - Part 1: General test

    • Why Partial Discharge Testing is Essential for Routine.Get Price!

      Well designed equipment which has been correctly assembled should typically exhibit very low partial discharge, typically below 10 picocoulombs at power frequency voltage. Partial discharge is the result of localised insulation failure occurring within a piece of equipment, typically at the point of maximum voltage stress at the positive and.




    Email: [email protected]

    Send your Inquiry

    Inquiry

    Using our contact forms you can also send inquiries, give feedback, request information and ask questions.
    Email:
    [email protected]